Use este identificador para citar ou linkar para este item: http://hdl.handle.net/11690/1891
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorZampieri, Fernando G.-
dc.contributor.authorOliveira, Neymar Elias de-
dc.contributor.authorNassar Junior, Antonio Paulo-
dc.contributor.authorManoel, Airton Leonardo de Oliveira-
dc.contributor.authorGrion, Cintia-
dc.contributor.authorLacerda, Fábio H.-
dc.contributor.authorMaia, Israel-
dc.contributor.authorThompson, Marlus-
dc.contributor.authorGiancursi, Thiago Simões-
dc.contributor.authorMartins, Priscilla de Aquino-
dc.contributor.authorLisboa, Thiago-
dc.contributor.authorAbait, Tamiris-
dc.contributor.authorDamiani, Lucas P.-
dc.contributor.authorMachado, Flávia R.-
dc.contributor.authorCavalcanti, Alexandre B.-
dc.date.accessioned2021-07-23T16:14:43Z-
dc.date.available2021-07-23T16:14:43Z-
dc.date.issued2020-
dc.identifier.citationZAMPIERI, F. G. et al. Bundle of Coated Devices to Reduce Nosocomial Infections in the Intensive Care Unit: CRITIC Pilot Randomized Controlled Trial. ATS Journals, v. 17, n. 10, p. 1257-1263, out. 2020. Disponível em: https://www.atsjournals.org/doi/pdf/10.1513/AnnalsATS.202003-206OC. Acesso em: 23 jul. 2021.pt_BR
dc.identifier.urihttp://hdl.handle.net/11690/1891-
dc.description.abstractRationale: Coated devices may reduce biofilm formation and reduce the occurrence of device-related infections in critically ill patients. A bundle of coated devices (an endotracheal tube [ETT], central venous catheter [CVC], and urinary catheter [UC]) simultaneously inserted may optimize benefits of coated devices in patients with the most severe illness.Objectives: To assess the feasibility of a randomized controlled trial on simultaneous insertion of gold/silver/palladium-coated devices versus uncoated devices in severely ill patients, which required sequential insertion of all three devices (an ETT, CVC, and UC) for support in the intensive care unit (ICU).Methods: This was a multicenter randomized controlled pilot trial. Patients who required simultaneous insertion of an ETT, CVC, and UC were randomized to treatment with coated versus uncoated devices, which were used as necessary for up to 28 days. The primary endpoint was feasibility, defined as the trial being able to enroll enough participants to have the sample size necessary for its secondary primary endpoint (estimating sepsis incidence in this population) in less than 1 year and for estimating the number of admitted patients who require simultaneous insertion of all three devices. Secondary endpoints included the incidence of sepsis and device-associated infections (ventilator-associated pneumonia, catheter-related bloodstream infection, and catheter-related urinary-tract infection) within each group as well as the number of days alive and free of antibiotics during the ICU stay. All events were adjudicated.Results: One hundred and three patients (48 in the coated-device group and 55 in the uncoated-device group) were included in the per-protocol analysis. The inclusion period was 8 months. There were 13 septic events in each group (26 in total), with an approximate incidence of sepsis of 32.3 (95% credible interval [CrI], 22.4-44.9) per 100 patient-days. The overall incidences of ventilator-associated pneumonia, catheter-related urinary-tract infection, and catheter-related bloodstream infection were 15.2 (95% CrI, 7.8-26.4), 6.3 (95% CrI, 2.4-13.7), and 7.9 (95% CrI, 3.6-15.1) per 1,000 patient-days, and incidence rates were not statistically different between groups. Patients in the coated-device group had more days alive and free of antibiotics in the ICU (28.97 d vs. 19.62 d per 100 patient-days; mean ratio, 1.48; 95% CrI, 1.16-1.89).Conclusions: Use of a bundle of coated devices as the initial treatment for of severely ill patients is feasible. Coated devices may be associated with more days alive and free of antibiotics.Clinical trial registered with www.clinicaltrials.gov (NCT03868241).pt_BR
dc.language.isoen_USpt_BR
dc.publisherAmerican Thoracic Societypt_BR
dc.rightsClosed Accessen
dc.subjectCoated devicespt_BR
dc.subjectHealth care–associated infectionspt_BR
dc.subjectSepsispt_BR
dc.subjectVentilator-associated pneumoniapt_BR
dc.titleBundle of Coated Devices to Reduce Nosocomial Infections in the Intensive Care Unit: CRITIC Pilot Randomized Controlled Trialpt_BR
dc.typeArtigopt_BR
Aparece nas coleções:Artigo de Periódico (PPGSDH)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Bundle of Coated Devices_AATS.pdf
  Until 2070-01-01
Closed Access1,15 MBAdobe PDFVisualizar/Abrir    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.